OPERATION

Automatic Reset Feature (ARF)

The Automatic Reset Feature (ARF) is designed to ensure that the

External Dock Lock (EDL) flipper plates are not trapped down while

the trailer is being operated. This is accomplished by the use of two

valves. A pilot valve is used to monitor emergency brake pressure to

determine if the trailer is parked or in motion. A sensor valve is used

to monitor the position of the EDL flipper plates (either up or down)

(FIGURE 10).

FIGURE 11

Primary Height Control Valve Detail

Sensor
Valve

Check Valve

Pilot Valve

Primary Height Control Valve

Emergency
Line

Sensor Valve

Primary Height
Control Valve

Pilot Valve

Check Valve

Link

Flipper Plate

Pressure Protection Valve

Emergency Line

To Actuator
Chamber

To actuator

chamber

Air Reservoir Tank

To air springs

To center port

of sensor valve

To PPV

To pilot

valve

To air springs

FIGURE 12

Automatic Reset Feature

The primary height control valve has full function under two

conditions: (1) parking brakes are engaged or disengaged with flipper

plates up or (2) parking brakes are engaged with flipper plates down. If
however, parking brakes are disengaged with flipper plates

down, the sensor valve will add air directly to the air springs.

After the air springs have sufficient air pressure to raise the flipper

plates up off the load pads, the flipper plates rotate up and out of the

way. This disengages the sensor valve and allows the primary height

control valve to resume full function (FIGURE 12).