33

Current output

(High) with BR-

7000-T Energized

NA

120 mA rms

NA

Voltage output

(Low)

De-Energized

NA

60 Vp-p

NA

Voltage output

(High)

De-Energized

NA

120 Vp-p

NA

Voltage output

(Clamp mode)

De-Energized

NA

180 Vp-p

1.5 Vp-p

Range Detection

(Open air)

Smart mode

Pinpointing: Around

1.97-in (5 cm) radius

(±2%)
Direction indication:

Up to 5FT (152.4cm)

(±2%)

TIP Sensor: Energized

Pinpointing: Around

1.97-in (5 cm) (±1%)
Detection: Up to 22-FT

(670.56cm) (±1%)

TIP Sensor: De-Energized

Detection: Up to 14-FT

(426.72cm) (±5%)

NCV (40-400 Hz)

Pinpointing: Around

1.97-in (5cm) radius

(±5%)
Detection: Up to 4-FT

(121.92cm) (±5%)

NA

NA

Jaw Opening

NA

NA

2-in (5.08cm)

Fuse

NA

3.15A , 600V MAX,

SLOW 5X20MM

NA

Dimensions

10.92x4.43x2.55-in

(27.75x11.25x64.83cm)

8.5x4x2.2-in

(21.59x10.16x5.59cm)

8.2x3.2x 1.68-in

(208.28 x 81.28x 42.67

mm)

Weight

1.20 lb (0.544 kg)

1.30 lb (0.593 kg)

0.648 lb (0.294 kg)

6. sPecifications