MVC 121 • Installation and Operation

Rear Panel Features and Cabling

MVC 121

ON

INPUTS

OUTPUT

S

LEVEL

48V

ON

OFF

MAIN 3

LINE

MIC

RS-232

MUTE

Tx Rx

POWER

12V
0.5A MAX

L

1

2

R

3

1

2

3

4

1 2 1 2

MIXER/VOLUME
CONTROLLER

FIXED

L

R

MIC 1

MIC 2

VARIABLE

L

R

7

8

1

2

3

5

4

6

1

Power connector

— Connect the included 12 VDC external

power supply into the 2-pole 3.5 mm captive screw connector.
Be careful to observe the correct polarity.

Orange Captive Screw

Connector

Tie Wrap

Power Supply

Output Cord

Ridges

Smooth

A

A

SECTION A–A

CAUTION

When connecting the power supply, voltage
polarity is extremely important. Applying power
with incorrect voltage polarity could damage the
power supply and the MVC 121. Identify the
power cord negative (ground) lead by the ridges on
the side of the cord or a black heat shrink wrapping
around it.

The two power cord wires must be kept separate
while the power supply is plugged in. Remove
power before wiring.

To verify the polarity before connection, check the no load
power supply output with a voltmeter.

CAUTION

The length of the exposed (stripped) copper wires is
important. The ideal length is 5/16” (7 mm)
.
Longer bare wires can short together. Shorter
wires are not as secure in the direct insertion
connectors and could be pulled out.

2-7