MVC 121 • Remote Control

Remote Control, cont’d

3-4

X2

= Input or output to be adjusted (1 – 4)

1 = mic 1
2 = mic 2
3 = main line level
4 = master output

X3

= On/off status

0 = off (mute)
1 = on (unmute)
2 = mute by contact closure

X4

= Input audio gain/attenuation value

( -79 through +12)

X5

= Audio gain (per input)

(0 – 12)

X6

= Audio attenuation (per input)

(1 through 79)

X7

= Controller firmware version (listed to two decimal places,

i.e., x.xx)

X8

= Front panel security lockout (executive modes)

0 = off
1 = mode 1 (lock all front panel controls except master
volume)
2 = mode 2 (lock all front panel controls)

X9

= Rear panel DIP switch settings (0 through 15)

See the following tables.

ON

LEVEL

4

8

V

ON - up

OFF - down

LINE

MIC

1

2

3

4

1 2 1 2

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

DIP switch 1

DIP switch 2

DIP switch 3

DIP switch 4

X9 =

Level

Mic 1

Level

Mic 2

48V

Mic 1

48V

Mic 2

Off

Off

Off

Off

Off

Off

Off

On

Off

Off

On

Off

Off

Off

On

On

Off

On

Off

Off

Off

On

Off

On

Off Off On On On On On On On On

On On Off Off Off Off On On On On

On On Off Off On On Off Off On On

Off On Off On Off On Off On Off On

DIP Switch Positions

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

DIP switch 1

DIP switch 2

DIP switch 3

DIP switch 4

X9 =

Level

Mic 1

Level

Mic 2

48V

Mic 1

48V

Mic 2

Mic

Mic

Off

Off

Mic

Mic

Off

On

Mic

Mic

On

Off

Mic

Mic

On

On

Mic

Line

Off

Off

Mic

Line

Off

Off

Mic Mic Line Line Line LineLineLine Line Line

Line Line Mic Mic Mic Mic LineLine LineLine

On On Off Off Off Off Off Off Off Off

Off Off Off On Off On Off Off Off Off

DIP Switch Functions