Using the command/response table – Extron Electronics MVC 121 User Manual

Page 29

Advertising
background image

MVC 121• Remote Control

3-3

is invalid or it contains invalid parameters, it returns an error
response to the host.

The error response codes and their descriptions are as follows:

E01 – Invalid channel number
E10 – Invalid command
E13 – Invalid value (the number is out of range)
E14 – Invalid command at this time (input on/off command not

valid during contact closure mute)

E23 – Firmware update failure

Using the command/response table

The command/response table lists valid command ASCII codes,
the MVC’s responses to the host, and a description of the
command’s function or the results of executing the command.
Lower case characters are acceptable in the command field only
where indicated. The ASCII to HEX conversion table below is
for use with the command/response table.

ASCII to HEX Conversion Table

The command/response table uses symbols (defined below) to
represent variables.

The SIS on/off commands and the equivalent front panel
operations have equal priority. The MVC will respond
to the latest settings from either SIS commands or front
panel operations.

Symbol definitions

= CR/LF (carriage return/line feed) (hex 0D 0A)

= Space
= Every response that could also be an unsolicited response

will have this symbol at the end of each description of that
response.

X1

= Master (output) volume adjustment range (0 – 92),

default = 50 (-30 dB), gain (dB) =

X1

- 80

Advertising