Remote control, cont’d – Extron Electronics MVC 121 User Manual

Page 34

Advertising
background image

MVC 121 • Remote Control

Remote Control, cont’d

3-8

Command

ASCII Command

Response

Additional description

(host to controller)

(controller to host)

Set volume range limit

Set volume range lower limit

4*

X1

*21#

Vll4

*

X1

Set the volume range lower limit to

X1

.

Set volume range upper limit

4*

X1

*22#

V

ul4

*

X1

Set the volume range upper limit to

X1

.

View volume range limit

V

iew volume range lower limit

4*21#

X1

Show the volume range lower limit

X1

.

V

iew volume range upper limit

4*22#

X1

Show the volume range upper limit

X1

.