Contact closure mute – Extron Electronics MVC 121 User Manual

Page 39

Advertising
background image

MVC 121 • Remote Control

Contact Closure Mute

For contact closure mute, connect a contact closure remote
control device to the rear panel’s female 6-pole captive screw
connector. The pin assignments for the MVC’s contact closure
mute connector are shown in the following table.

Pin Contact closure Description

1

Connect pin 1 to Gnd

Mute input Mic 1

2

Connect pin 2 to Gnd

Mute input Mic 2

3

Connect pin 3 to Gnd

Mute input Main 3

Gnd

Signal ground

Contact closure mute has higher priority over both SIS
commands and front panel operations and is not affected
by either SIS commands or front panel operations.

After contact closure mute has been removed, the input
settings will return to the original settings that were in
effect prior to the mute, including input on/off status
and gain setting.

3-13

Advertising