Hardware Installation

MVI94-MCM ♦ Flex I/O Platform

User Manual

Serial Communications Modbus Communication Module

Page 14 of 109

ProSoft Technology, Inc.

March 29, 2011

2.3

Setting Jumpers

Before installing the MVI94 module onto its base, the module’s configuration can

be set using the jumpers on the bottom of the module as shown in this figure.

Port 2 RS-232/422/485: Select with jumper (shipped in 232).
BP Reset: If the MVI94 module is to be reset when the Flex Bus is reset, install

the BP RESET jumper in the Enabled position.

ATTENTION: Do not remove or replace a base unit when power is applied. Interruption of the
flexbus can result in unintended operation or machine motion.

SETUP: To place the module in SETUP mode, install the jumper in the Selected
position (DOS default). To prevent the module from being in Setup mode, leave

the jumper in the disabled position.