Installation – ProSoft Technology AN-X-PB User Manual

Page 11

Advertising
background image

AN-X-PBSLV Page

5

January 2008

Installation

Prevent Electrostatic Discharge

The module is sensitive to electrostatic discharge.

WARNING!

Electrostatic discharge can damage integrated circuits or
semiconductors. Follow these guidelines when you handle the module:

Touch a grounded object to discharge static potential

Do not touch the connector pins

Power

AN-X requires a DC power input of anywhere from 12 to 24 VDC.

Left to right the pins on the power connector are chassis ground, negative
voltage and positive voltage.

The chassis ground should be connected.

Power consumption internally is 300 mA @ 12VDC or 150 mA @
24VDC.

The part number for the power connector is Phoenix MSTB
2.5/3-ST-5.08

Cabling and Termination

Use a cable with a standard PROFIBUS 9-pin connector to connect the
module to the network.

The network must be terminated at the physical ends of the network.
There should be two and only two terminators on the network.

Advertising