Sending the configuration to an-x, Error log – ProSoft Technology AN-X-PB User Manual

Page 47

Advertising
background image

AN-X-PBSLV Page

41

January 2008

,consume

,,producer_ip,192.168.0.9

,,block_id,1,5000

,,,Node1Outputs,U8,2,7,I/0

Sending the Configuration to AN-X

When the configuration is complete, save it to a file. If you are using a
spreadsheet to create the configuration, save it as a file of type comma
separated variable (CSV).

To upload the configuration:

1.

Start your web browser

2.

Enter the AN-X IP address as the address, for example, 192.168.0.9

3.

Select Automation Network/Configure AN-X Bridging Server

4.

Browse or type in the configuration file name

5.

Click Send File to AN-X

If the file is processed successfully, the web interface shows the
configuration. If an error occurs, the web interface gives an error
message. To see further details, select Log Files/Bridging Log (see page
64) and check for error messages at the end of the log.

Error Log

Errors that occur during configuration of AN-X to AN-X communication
or during operation are logged in the Bridging Log.

You can view the log using the AN-X web interface. Select Log
Files/Bridging Log
to view the log.