11 i/o, 12 power management, 13 system management – Endura RADISYS KP915GV User Manual

Page 30: 14 security

Advertising
background image

KP915GV Product Manual

30

2.11 I/O

Four USB 2.0 ports on I/O panel via two dual stacked USB over RJ45 connectors

Four USB 2.0 ports on internal locking headers

Available with IEEE 1394b controller with support for 1394a

Single port via a header connector

Based on Texas Instruments TSB82AA2 controller and TSB81BA3 transceiver

2.12 Power

Management

Supports ACPI 2.0 with power states S0, S3, S4 (not S4BIOS), S5 and C0, C1, C2, C3

Supports PCI PME and PCI Express power management event signaling

Table 3. ACPI Power States

G0/S0/C0 Full

on

G0/S0/C1

Processor is halted

G0/S0/C2

Processor stops internal clocks

G0/S0/C3

Processor clocks are disabled and processor in sleep state

G1/S3

System context is saved to RAM and power removed from all circuits
except that required to maintain system RAM and resume

G1/S4

System context is saved to disk and power removed from all circuits
except that required to resume

G2/S5

Soft off, only resume logic and RTC remain powered

2.13 System

management

System monitoring of voltage, temperature, fans

Temperature monitoring of processor die, board and remote sensor

Direct monitoring of lithium cell voltage

Automatic fan control for 3 fans - CPU, System 1, System 2

Fan configuration held in BIOS customization block

Fans can be assigned to any of three thermal zones for automatic control - each zone

monitored by one of the three thermal sensors

450mA drive capability for each system fan, 2.2A for the CPU fan

Anti-tamper security (trigger for chassis intrusion detect)

Programmable watchdog timer with range of 1 second to 1 hour

Access to SMBus via 4-pin 2mm header

2.14 Security

Header for Trusted Platform Module (TPM)

TCG 1.1 compliant

Advertising