Table 5. Environmental Specifications

Characteristic

State

Value

Operating 0

o

C to +55

o

C

Operation above +30

° C reduces the maximum operational

relative humidity.

Operating
gradient

±5

°C per minute

Temperature
(ambient)

Storage

-40

o

C to +85

o

C, 5

°C per minute maximum excursion

gradient.

Operating

10% to 85% RH non-condensing at +30

o

C, linearly

decreasing to 5% to 15.5% RH non-condensing at +65

o

C.

Relative
humidity

Storage

5% to 90% RH non-condensing at +40

o

C.

Operating

Random 5Hz to 2kHz, 7.7grms, 10 mins in each of 3 axes

5Hz to 20Hz: 0.004g2/Hz ramping up to 0.04g2/Hz;

20Hz to 1000Hz: 0.04g2/Hz;

1000Hz to 2000Hz: 0.04g2/Hz ramping down to
0.01g2/Hz

Vibration

Packaged

Random 5Hz to 2kHz, 9.7grms, 10 min. in each of 3 axes

5Hz to 20Hz: 0.006g2/Hz ramping up to 0.06g2/Hz;

20Hz to 1000Hz: 0.06g2/Hz;

1000Hz to 2000Hz: 0.06g2/Hz ramping down to
0.02g2/Hz

Sine 5Hz to 500Hz, 0.15 octave/min up and back, 10 min.
dwell at 3 resonances in each of 3 axes

5 to 50Hz swept – 0.1g; 50 to 500Hz swept – 0.25g

Non-
operating

30g 11ms, half-sine

Shock

Packaged

Drop test, 10-up bulk packaging, 30 inches free-fall, 152
inches/s velocity change

Operating

To 15000 ft. (4500m)

Altitude

Storage

To 40000 ft. (12000m)

MTBF

The table below summarizes the MTBF (hr) predictions for
the listed products, without the main processor, memory, or
battery installed.

SKU

35°C 55°C

KPGV1W00

298,735 141,946

KPGV1G00 295,736 156,014

KPGVFG00 280,528 147,801

Airflow

Base on standard Intel guidelines

Fuses

Self-resetting PTC fuse (fuses automatically reset without
user intervention once the load had been removed)