LG 55TC3CG-H 55" 4K UHD HDR Touchscreen Commercial Monitor User Manual

Page 141

Advertising
background image

ENGLISH

105

87. [Time to OFF] Scheduling (Command: f e)

Sets Off Timer settings.

Transmission

(f)(e)( )(Set ID)( )(Data1)( )(Data2)( )(Data3)(Cr)
Data1

1. f1h to f7h (data reading)

F1: Reads the 1st Timer Power Off’s data

F2: Reads the 2nd Timer Power Off’s data

F3: Reads the 3rd Timer Power Off’s data

F4: Reads the 4th Timer Power Off’s data

F5: Reads the 5th Timer Power Off’s data

F6: Reads the 6th Timer Power Off’s data

F7: Reads the 7th Timer Power Off’s data

2. e1h to e7h (Deletes one index), e0h (Deletes all

indexes)

E0: Delete all Timer Power Off’s

E1: Delete the 1st Timer Power Off

E2: Delete the 2nd Timer Power Off

E3: Delete the 3rd Timer Power Off

E4: Delete the 4th Timer Power Off

E5: Delete the 5th Timer Power Off

E6: Delete the 6th Timer Power Off

E7: Delete the 7th Timer Power Off

3. 01h to 0ch (Timer Power Off days setting)

02: Repeat Daily

03: Repeat from Monday to Friday

04: Repeat from Monday to Saturday

05: Repeat from Saturday to Sunday

06: Repeat on Sunday

07: Repeat on Monday

08: Repeat on Tuesday

09: Repeat on Wednesday

0A: Repeat on Thursday

0B: Repeat on Friday

0C: Repeat on Saturday

Data2 00-17: 00 - 23 hours

Data3 00-3B: 00 - 59 minutes

* To read or delete a Timer Power Off you have set, [Data2]

[Data3] must be set to FFH.

Example 1: fe 01 f1 ff ff - Reads the 1st index data in Timer

Power Off.

Example 2: fe 01 e1 ff ff - Reads the 1st index data in Timer

Power Off.

Example 3: fe 01 04 02 03 - Sets the Timer Power Off as

Monday - Saturday 02:03.

* This feature only works when Clock 1 (year/month/day) and

Clock 2 (hour/minute/second) have been set.

Acknowledgment

(e)( )(Set ID)( )(OK/NG)(Data1)(Data2)(Data3)(x)

88. LCIN008 Control (Command: s n, b8)

It controls the LCIN008 device.

Transmission

(s)(n)( )(Set ID)( )(b)(8)( )(Data1)(Data2)(Cr)
Data 1 00: LCIN008 Power

01: LCIN008 Brightness

Data 2

1. For Power

0 x 00: Off

0 x 01: On

2. For Brightness

0 x ff: Read

0 x 00 ~ 0 x 64: Applies a set value
Acknowledgement

(n)( )(Set ID)( )(OK/NG)(b)(8)(Data1)(Data2)(x)

* This feature may not be available for all models.

* Other commands do not work for a certain time after

applying.

89. [Transfer Control] (Command: s n, cb)

It transfers the command to RS232C out.

Transmission

(s)(n)( )(Set ID)( )(c)(b)( )(Data)(Cr)
Data Data that goes out to RS232C out
Acknowledgment

(n)( )(Set ID)( )(OK/NG)(c)(b)(Data)(x)
Data Response value of Data transferred to RS232C

out

* This feature may not be available for all models.

* Other commands do not work for a certain time after

applying.

90. Multichannel (Command: s n, 76)

It changes the channel.

Transmission

(s)(n)( )(Set ID)( )(7)(6)( )(Data)(Cr)
Data 01 - 09: Channel to switch to
Acknowledgment

(n)( )(Set ID)( )(OK/NG)(7)(6)(Data)(x)

* This feature may not be available for all models.