Commands and Responses Overview

The external control protocol is standard ASCII based. ESCX is the four letter preamble that is used for all commands. This preamble must
be uppercase. The commands provided in this protocol allow an external control system to navigate the Escient products, get library informa-
tion to build custom user interfaces, perform transport controls, and receive unsolicited feedback on system status.

All external control commands are made up of the preamble (ESCX), command group (01,02,10,20,50,70), sub command (specific task),
specific data (# of data items, and a size of data packet then the actual data packet repeated for the # of data items), and a carriage return end
marker.

External Control Command Structure

DESCRIPTION

PREAMBLE

COMMAND

GROUP

SUB COM

-

MAND

# DA

TA

ITEMS

DA
TA

ITEM

#1 SIZE

DA
TA

#1

DA
TA

ITEM

#2 SIZE

DA
TA

#2

END

MARKER

Bytes

4

2

2

3

4

5

4

3

1

Example

ESCX

01

08

002

0005

Hello

0003

Bye

Carriage Return

The external control commands are broken down into the following Command Groups:

01 – Command Responses
02 – Unsolicited Events
10 – Remote Button / Keyboard Commands
20 – Database Commands
50 – Status Commands
70 – Control Commands