Resetting the unit, Resetting the unit -10, Installation and operation, cont’d – Extron electronic IPL T S Series User Manual

Page 22

Advertising
background image

Installation and Operation, cont’d

IPL T S Series • Installation and Operation

2-10

IPL T S4

R

100

LINK

ACT

1

COM

TX

2

RX

R

TS

CTS

3

TX

4

RX

R

TS

CTS

9

7

8

1

3

2

4

5 6 3 4

5 6

Figure 2-13 — IPL T S4 front panel

IPL T S6

R

100

LINK

ACT

1

COM

TX

2

RX

R

TS

CTS

3

COM

TX

4

5

6

RX

TX

RX

1

3

2

4 5

6

9

7

8

3

4

3

4

Figure 2-14 — IPL T S6 front panel

a

Power LED — A green LED lights to indicate that the interface is receiving

power.

b

Reset button (recessed) — A multi-function reset button.

See “Resetting the

unit” later in this chapter for more information.

c

TX LEDs — A green LED indicates data is being transmitted from the

corresponding serial port.

d

RX LEDs — A green LED indicates data is being received by the

corresponding serial port.

e

RTS LEDs A green LED indicates that the corresponding serial port is

ready to send data.

f

CTS LEDs A green LED indicates that the device controlled by the

corresponding serial port is ready to accept data.

g

ACT (Activity) LED — A yellow LED indicates that data is being sent/

received.

h

LINK LED — A green LED indicates that the unit is connected to an active

network.

i

100 LED — A green LED indicates that the connection speed is 100 Mbps. If

the LED is not lit, the connection speed is 10 Mbps.

Resetting the unit

There are five reset modes available by pressing the Reset button (b) on the side

panel. The Reset button is recessed, so use a pointed stylus, ballpoint pen, or

Extron Tweeker to access it. See the following table for a summary of the modes.

C

Review the reset modes carefully. Using the wrong reset mode may result

in unintended loss of flash memory programming, port reassignment, or a
controller reboot.

C

The reset modes listed below (with the exception of Mode 2) close all open IP

and Telnet connections and close all sockets.

Advertising