background image

4-27

IPL T S Series • Communication and Control

COM 1

LAN

12V

.5A

MA

X

COM 3

LAN

UID# 093012052

PO

WER

12V

.5A MA

X

COM 2

COM 1

COM 2

RS-232

Plasma Display

Box 1

Box 2

PC running serial
control software or
a serial controller.

Extron

IPL T S4

Ethernet Control
Interface

RS-232

Ethernet

Extron

IPL T S1

Ethernet Control
Interface

TCP/IP

Network

Figure 4-10 — Setup for serial bridging

4. For IPL T S unit 2, make a serial connection to the PC or controller that will

control the remote A/V device.

5.

On the same device, follow the step 2 instructions.

You are now ready to configure IPL T S unit 2 for serial bridging mode.

Serial bridge configuration

To allow both IPL T S units to communicate together, you must configure unit 2 to

communicate with unit 1.

N

If a driver was previously loaded onto your IPL T S device COM port(s) using

Global Configurator, serial bridging disables it.

To configure unit 2 to communicate with unit 1:

1.

Enter the IP address of unit 2 in the Internet browser’s Address field at the top

of the screen, and press the Enter key.

The System Status page opens, showing the current IP and port settings of the

unit.

2.

Access the Web server port setting screen by clicking the Configuration tab,

then the Port Settings link on the left side of the window.

The Port Settings page appears, as shown in the figure below.

3.

Choose the serial port that you wish to communicate through.

4.

Under Serial Bridging, choose the On radio button to activate serial bridging

mode.