Error responses – Extron electronic IPL T S Series User Manual

Page 45

Advertising
background image

4-5

IPL T S Series • Communication and Control

are the same for both administrator and user, the unit defaults to administrator

privileges.

Error responses

When the IPL T S interface receives a valid command, it executes the command and

sends a response to the host device. If the unit is unable to execute the command

because the command contains invalid parameters, it returns an error response to

the host.
E12 — Invalid port number
E13 — Invalid parameter
E14 — Not valid for this configuration
E17 — System timed out
E22 — Busy
E24 — Privilege violation
E25 — Device not present
E26 — Maximum number of connections exceeded
E27 — Invalid event number
E28 — Bad filename/file not found

References to errors (at command descriptions on the following pages)

13

= Commands that give an E13 (invalid parameter) error

24

= Commands that give an E24 (privilege violation) error if not

administrator level

27

= Commands that may give an E27 (invalid event number)

error

28

= Commands that may give an E28 (file not found) error

Advertising