A b r 0 a a 0 1 0 b c a – Eaton Compressor & Fabrication C-STOV-MC001-E1 User Manual

Page 23

Advertising
background image

EATON Steering Catalog C-STOV-MC001-E1 May 2006

23

Steering Control
Units—Series 5

Model Code –
Ordering
Information

The following 30-digit coding system has been developed to
identify all of the configuration options for the Series 5
steering control units. Use this model code to specify a unit
with the desired features. All 30-digits of the code must be
present when ordering. You may want to photocopy the
matrix below to ensure that each number is entered in the
correct box.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28

29

30

A B R

0

A

A 0

1

0

B

C

A

Nos

Feature

Code Description

Nos

Feature

Code Description

1,2,3

Product Series

ABR

Series 5 Steering Control Unit

4

Nominal Flow

1

11 l/min [3 GPM]

Rating

B

19 l/min [5 GPM]

5

Inlet Pressure

C

140 bar [2030 PSI]

Rating

6

Tank Pressure

A

10 bar [150 PSI]

Rating

B

21 bar [300 PSI]

7-8

Displacement 35

31.5

cm3/r [1.92 in3/r]

37

39.5 cm3/r [2.41 in3/r]

39

50.8 cm3/r [3.10 in3/r]

41

63.1 cm3/r [3.85 in3/r]

43

73.8 cm3/r [4.50 in3/r]

46

100 cm3/r [6.10 in3/r]

48

120 cm3/r [7.33 in3/r]

9

Flow Amplification 0

None

10

Neutral Circuit

A

Open Center

B

Open Center, Power Beyond

F

Load Sensing, Dynamic signal

11

Load Circuit

A

Non-Load Reaction

12,13

Valve Options

01

Manual Steering Check Valve

04

Inlet Check Valve, Manual
Steering Check Valve

05

Inlet Relief Valve,
Manual Steering Check Valve

12

Cylinder Relief Valve,
Anti-Cavitation Valve,
Inlet Relief Valve,
Inlet Check Valve,
Manual Steering Check Valve.

13

Cylinder Relief Valve,
Anti-cavitation Valve, Inlet Check
Valve, Load Sensing Relief Valve,
Manual Steering Check Valve

14,15

Integral Inlet

00

None

Relief Valve

18

40 bar [580 PSI]

Setting

1J

50 bar [725 PSI]

1Z

63 bar [914 PSI]

26

70 bar [1015 PSI]

2G

80 bar [1160 PSI]

2T

90 bar [1305 PSI]

34

100 bar [1450 PSI]

3W

125 bar [1812 PSI]

16,17

Cylinder Relief

00

None

Setting

37

103 bar [1490 PSI]

42

130 bar [1890 PSI]

55

185 bar [2680 PSI]

68

200 bar [2900 PSI]

18,19,20,21

Ports and

4AAN

Square 4 x 9/16 SAE Ports,

Mounting Threads

M10 x 1,5 Column Mounting
Threads (Use with Open Center)

4AKN

Square 5 x 9/16 SAE Ports,
M10 x 1,5 Column Mounting
Threads (Use with Excess Flow)

4AEN

Square 5 x 9/16 SAE Ports,
M10 x 1,5 Column Mounting
Threads (Use with Load Sense)

UAAN

Square 4 x -06 STC Direct
Ports, M10 x 1,5 Column
Mounting Threads (Use with
Open Center)

UBNN

Square 5 x -06 STC Direct
Ports, M10 x 1,5 Column
Mounting Threads
(Use with Excess Flow)

UBPN

Square 5 x -06 STC Direct
Ports, M10 x 1,5 Column
Mounting Threads
(Use with Load Sense)

YAAN

Square 4 x G .375 BSP Striaght
Thd. Ports, M10 x 1,5 Column
Mounting Threads
(Use with Open Center)

YBRN

Square 5 x G .375 BSP Striaght
Thd. Ports, M10 x 1,5 Column
Mounting Threads
(Use with Load Sense)

22

Input Torque

1

Low*

3

Standard

23

Fluid Type

A

See Eaton Technical
Bulletin 3-401

24

Special Application 0

None

25,26

Special Feature

AA

None

27

Paint

1

Black Primer

28

Identification

0

Eaton Product Number on
Nameplate

29

Mechanical A

Tapered 17.919mm (.7055in)

Interface

diameter, .083:1 and serrated
17.5 (.688) diameter, 40 tooth,
M16x1.5-6g, Extension length
65.02 (2.56)

D

Internal involute spline12 tooth,
16/32 DP, 30 degree PA

30

Eaton Assigned

B

Assigned Design Code

Design Code

* All low torque units need approval from an Eaton Steering Engineer.

Square Housing with Side Ports - Option 1

Advertising