Eaton Compressor & Fabrication C-STOV-MC001-E1 User Manual

Page 9

Advertising
background image

EATON Char-Lynn Steering Catalog C-STOV-MC001-E1 July 2006

9

Hydraulic Circuit
Explanation

Neutral Circuits:
Load Sensing

T

LS

P

LS CF

EF

R

L

P

T

High Pressure
Carryover to
Auxiliary Circuit with
Open Center Valve(s)

Fixed Displacement Pump

Load Sensing Steering System with Fixed
Displacement Pump (Open Center Circuit)

Load
Sensing
(Dynamic
Signal)
Steering
Control Unit
(non-load
reaction)

Priority Valve
(Dynamic Signal)

Dynamic
Signal

T

LS

P

LS CF

EF

R

L

T

P

Auxiliary
Circuit with
Load Sensing
Valve(s)

Pilot Signal
from Auxiliary
Circuit

Pressure and Flow
Compensated Pump

Shuttle Valve

Load Sensing Steering System with Pressure and Flow
Compensated Pump (Closed Center, Load Sensing Circuit)

Load
Sensing
(Dynamic
Signal)
Steering
Control Unit
(non-load
reaction)

Priority Valve
(Dynamic Signal)

Dynamic
Signal

Dynamic Signal—
Open Center Pump

Dynamic Signal—
Load Sensing Pump

Load Sensing Circuits—
Signal Systems

Two types of load sensing
signal systems are
available—Dynamic and
Static.

Dynamic Signal—Used for
more difficult applications.
The dynamic signal systems
offer the following benefits:

• Faster steering

response.

• Improved cold weather

start-up performance.

• Increased flexibility to

solve problems related
to system performance
and stability.

Advertising