Torque generator conventional system circuits – Eaton Compressor & Fabrication C-STOV-MC001-E1 User Manual

Page 58

Advertising
background image

58

EATON Char-Lynn Steering Catalog C-STOV-MC001-E1 July 2006

Torque Generator

Conventional
System Circuits

Load Sensing System

• Steering has priority

• Auxiliary function can

operate at higher
pressure than steering
rating; priority valve
isolates CF side from EF
side pressures.

• Flow to auxiliary

functions reduced while
steering

Pump

Torque
Generator

In

Out

LS

Priority
Valve

CF

EF

Valve

Cylinder

Torque
Generator

Relief Valve

In

Out

Case Drain

Pump

Relief Valve

Valve

Cylinder

High Back Pressure Torque
Generator

• Series circuit; auxiliary

and steering pressures
are additive

• All flow available to

auxiliary function, even
while steering

• Separate relief valves

required for steering
and auxiliary