Grounding, Pressure ratings, Step 5 grounding – Emerson CMF200A User Manual

Page 22

Advertising
background image

20

Micro Motion

®

ELITE

®

Sensors

Grounding

Step 5

Grounding

The sensor can be grounded via the piping if the joints in the pipeline are ground-bonded. If the sensor is not
grounded via the piping, connect a ground wire to the internal or external grounding screw, which is located
on the transmitter, core processor, or junction box.

Improper grounding can cause measurement error. Ground the flowmeter to earth, or follow ground
network requirements for the facility.

If national standards are not in effect, follow these guidelines to ground the sensor:

• Use copper wire, 14 AWG (2,0 mm²) or larger wire size for grounding.

• Keep all ground leads as short as possible, less than 1 ohm impedance.

• Connect ground leads directly to earth, or follow plant standards.

Pressure Ratings

Table 4 shows the pressure ratings for ELITE sensors.

1. Pressure rating limited by flange (for 304 sensor tubes).
2. Pressure rating limited by flange (for 316 sensor tubes).
3. Pressure rating limited by flange (for C-22 Alloy sensor tubes).

Table 4

ELITE pressure ratings

EN-1092 flange

Pressure rating (bar)

Note

PN

Type

Facing

Description

ASTM

material

50°C 100°C 150°C 200°C 250°C 300°C 350°C 400°C 427°C

40

11

weld
neck

B1

Flange, EN

1092-1 PN40

Form B1 (304)

304

40.0

34.4

30.8

28.0

26.0

24.1

23.0

22.0

21.4

1

40

11

weld
neck

B2 & D

Flange, EN

1092-1 PN40

Form B2 & D

(316)

316

40.0

40.0

36.3

33.7

31.8

29.7

28.5

27.4

26.9

2

100

11

weld
neck

B2 & D

Flange, EN

1092-1 PN100

Form B2 & D

(316)

316

100.0 100.0

90.9

84.2

79.5

74.2

71.4

68.5

67.3

2

40

32/02

lap

joint

B1

Flange, EN

1092-1 PN40

Form B1(lap

joint)

C-22 collar/

304 flange

40.0

34.4

30.8

28.0

26.0

24.1

23.0

22.0

21.4

3

Advertising