Typical RS422 and RS485 connection

RS485 MULTI-DROP

RS422 POINT-TO-POINT

RS422 MULTI-DROP

Number of Wires

5

Transmitters Enabled

always

Receivers Enabled

always

Duplex Mode

full

LK6 B
LK7

B

Number of Wires

5

Transmitters Enabled

active RTS

Receivers Enabled

always

Duplex Mode

full

LK6 B
LK7

B

Number of Wires

3

Transmitters Enabled

active RTS

Receivers Enabled

always

Duplex Mode

half

LK6 A

LK7 A