Installation method #2, Side mount packaged refrigeration system – Heatcraft Refrigeration Products PRO3 User Manual

Page 5

Advertising
background image

PRO

3

Side Mount Packaged Refrigeration System Installation and Operations Manual, May 008

5

PRO

3

Side Mount Packaged Refrigeration System

Installation Method #2

Side Installation (See FIGURES 7, 8, and 9)

This installation method is intended for applications that have
height restrictions that do not allow the unit to be installed from
above (see method #1) and installations into pre-existing boxes
where it is impractical to remove the roof.

In order to install a unit using this method, you must provide an
additional “plug” section of the box to fill in the open space between
evaporator arms after installation. This section should contain cam
locks to anchor it in place.

Please use the following guidelines when completing the installation
in this manner.
1. Provide a finished opening with the appropriate dimensions

from FIGURE 8 or 9.

.

The cut-out section should not be placed in a location where it

would degrade the structural integrity of the box (should not

interfere with cam locks)

3. The unit will need to be lifted to the appropriate height and

inserted into the open slot. The bottom of the unit should be

temporarily supported during the remainder of the installation

process (no portion of the unit should be supported by the

bottom of the evaporator section as this WILL cause damage to

the drain pan).

4. You should use cam locks to re-connect the “plug” section after

installing the unit, firmly attach the unit to the box and carefully

seal all seams.

SEE PLUG DETAIL

29.00

20.07

CAMLOCKS

4 PLACES

20.00

23.00

CAMLOCKS

4 PLACES

FIGURE 7: Plug Detail

FIGURE 9: Plug Detail | Large Cabinet

FIGURE 8: Plug Detail | Small Cabinet

Advertising