Application configuration URL
URL: /setup/app.cgi
NAME VALUE
DESCRIPTION
emode
<not required>
event mode application
smode <not
required>
sequential mode application
upload snapshots by email
smethod
ftp
upload snapshots by FTP
suffix
<not required>
FTP file with date and time suffix
delay
<integer>
seconds delay to detect next event
inter
<integer>
seconds delay to capture post-event
dihigh
< not required >
set DI high as trigger condition
dilow
< not required >
set DI low as trigger condition
dirise
< not required >
set DI rising as trigger condition
difall
< not required >
set DI falling as trigger condition
motion1
< not required >
set motion window1 as trigger condition
motion2
< not required >
set motion window2 as trigger condition
motion3
< not required >
set motion window3 as trigger condition
ioalarm
< not required >
trigger DO when DI condition matched
mdalarm
< not required >
trigger DO when motion detected
ioupload
< not required >
upload snapshot when DI condition matched
mdupload < not required >
upload snapshot when motion detected
sinter
<integer>
seconds interval for sequential mode
sbegin
<hh:mm:ss>
time to start sequential mode
send
<hh:mm:ss>
time to stop sequential mode
50