C. Clearances

NOTICE: Install appliance on hard metal or wood surfaces

extending full width and depth.

DO NOT install directly

on carpeting, vinyl, tile or any combustible material other

than wood.
WARNING! Risk of Fire! Maintain specified air space

clearances to appliance and vent pipe:
• Insulation and other materials must be secured to prevent

accidental contact.

• The chase must be properly blocked to prevent blown

insulation or other combustibles from entering and

making contact with fireplace or chimney.

• Failure to maintain airspace may cause overheating and

a fire.

D. Mantel and Wall Projections

WARNING! Risk of Fire! Comply with all minimum clear-

ances as specified. Framing or finishing material closer than

the minimums listed must be constructed entirely of noncom-

bustible materials (i.e., steel studs, concrete board, etc).

Figure 5.3 Minimum Vertical and Maximum Horizontal

Dimensions of Combustibles

Combustible Mantels

MEASUREMENTS FROM

TOP EDGE OF THE OPENING

5

10

11

12

2-1/2

13

14

15

16

17

18

19

32

TO CEILING

9

10

11

12

8

7

6

5

4

3

25

18

Note: All

measurements

in inches.

Note: Measurement is taken from top of the opening,

NOT the top of the fireplace.

1 in. (25 mm) min.

to perpendicular wall

A

3-1/2 in. (89 mm) min.

from fireplace opening

to perpendicular wall

B

Mantel Leg or

Perpendicular Wall

Top of

Appliance

Drywall

A

B

Figure 5.4 Mantel Leg or Wall Projections (Acceptable on both

sides of opening)

Mantel Legs or Wall Projections

Advertising