Listing and code approvals – Hearth and Home Technologies Hearth&Home Fireplace BV4236DBI User Manual

Page 7

Advertising
background image

7

Hearth & Home Technologies • BV4236DBI, BV4842DBI • 2209-900 Rev. N • 9/12

B. Glass Specifications

Hearth & Home Technologies appliances manufactured

with tempered glass may be installed in hazardous loca-

tions such as bathtub enclosures as defined by the Con-

sumer Product Safety Commission (CPSC). The tempered

glass has been tested and certified to the requirements

of

ANSI Z97.1 and CPSC 16 CFR 1202 (Safety Glazing

Certification Council

SGCC# 1595 and 1597. Architectur-

al Testing, Inc. Reports

02-31919.01 and 02-31917.01).

This statement is in compliance with

CPSC 16 CFR Sec-

tion 1201.5 “Certification and labeling requirements”

which refers to

15 U.S. Code (USC) 2063 stating “…Such

certificate shall accompany the product or shall otherwise

be furnished to any distributor or retailer to whom the

product is delivered.”
Some local building codes require the use of tempered

glass with permanent marking in such locations. Glass

meeting this requirement is available from the factory.

Please contact your dealer or distributor to order.

C. BTU Specifications

This product is listed to ANSI standards for “Vented Gas

Fireplaces” and “Gas Fired Appliances for Use at High

Altitudes”.
May be installed in a sleeping room when the provisions

for combustion, ventilation and dilution air are met per the

requirements of

ANSI 223.1/NFPA 54 National Fuel Gas

Code. In Canada, installation in a sleeping room requires

installation with a thermostat certified for use with this prod-

uct. Consult your local authorities having jurisdiction.
NOTICE: This installation must conform with local codes.

In the absence of local codes you must comply with the

National Fuel Gas Code, ANSI Z223.1-latest edition in

the U.S.A. and the CAN/CGA B149 Installation Codes in

Canada.

A. Appliance Certification

NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.

This appliance is tested and approved as either supplemen-

tal room heat or as a decorative appliance. It should not be

factored as primary heat in residential heating calculations.

D. High Altitude Installations

NOTICE: If the heating value of the gas has been reduced,

these rules do not apply. Check with your local gas utility

or authorities having jurisdiction.
When installing above 2000 feet elevation:
• In the USA: Reduce input rate 4% for each 1000 feet

above 2000 feet.

• In CANADA: Reduce input rate 10% for elevations

between 2000 feet and 4500 feet. Above 4500 feet,

consult local gas utility.

Check with your local gas utility to determine proper orifice

size.

E. Non-Combustible Materials Specification

Material which will not ignite and burn. Such materials are

those consisting entirely of steel, iron, brick, tile, concrete,

slate, glass or plasters, or any combination thereof.

Materials that are reported as passing

ASTM E 136,

Standard Test Method for Behavior of Materials in a

Vertical Tube Furnace at 750 ºC and UL763 shall be

considered non-combustible materials.

F. Combustible Materials Specification

Materials made of or surfaced with wood, compressed pa-

per, plant fibers, plastics, or other material that can ignite

and burn, whether flame proofed or not, or plastered or

unplastered shall be considered combustible materials.

G. Electrical Codes

NOTICE: This appliance must be electrically wired and

grounded in accordance with local codes or, in the absence

of local codes, with

National Electric Code ANSI/NFPA

70-latest edition or the Canadian Electric Code CSA

C22.1.
• A 110-120 VAC circuit for this product must be pro-

tected with ground-fault circuit-interrupter protection,

in compliance with the applicable electrical codes,

when it is installed in locations such as in bathrooms

or near sinks.

1

Listing and Code Approvals

MODELS: BV4236DBI, BV4842DBI
LABORATORY:
Underwriters Laboratories, Inc. (UL)
TYPE:
B-Vent Gas Appliance
STANDARD:
ANSI Z21.50b-2009 • CSA 2.22b-2009

Models

U.S. (0-2000 ft.) or Canada (2000-4500 ft.)

Maximum

Input BTU/h

Minimum

Input BTU/h

Orifice

Size

(DMS)

BV4236DBI

US

30,000

17,000

37

CAN

27,100

15,300

38

BV4236DBI (LP)

US

30,000

16,000

52

CAN

27,000

14,400

53

BV4842DBI

US

35,000

19,500

35

CAN

31,500

17,550

36

BV4842DBI (LP)

US

32,500

18,000

51

CAN

29,250

16,200

52