A. Mantel and Wall Projections

WARNING! Risk of Fire! Comply with all minimum clear-

ances as specified. Framing closer than the minimums list-

ed must be constructed entirely of noncombustible materials

(i.e., steel studs, concrete board, etc.).

13

Finishing

B. Facing Material

• Metal front faces may be covered with non-combustible

materials only.

• Facing and/or finishing materials must not interfere with

air flow through louvers, operation of louvers or doors,

or access for service.

• Facing and/or finishing materials must never overhang

into the glass opening.

• Observe all clearances when applying combustible

materials.

• Seal joints between the finished wall and appliance top

and sides using a 300ºF minimum sealant. Refer to

Figure 13.3.

WARNING! Risk of Fire! DO NOT apply combustible

materials beyond the minimum clearances. Comply with

all minimum clearances to combustibles as specified in

this manual. Overlapping materials could ignite and will

interfere with proper operation of doors and louvers.

Figure 13.2 Combustible Mantel Leg or Wall Projections

(Acceptable on both sides of opening)

Figure 13.1 Minimum Vertical and Maximum Horizontal

Dimensions of Combustibles

Combustible Mantels

Combustible Mantel Legs or Wall Projections

Note: All

measurements

in inches.

Note: Measurement is taken from top of the opening,

NOT the top of the fireplace.

Figure 13.3 Noncombustible Facing Diagram

B

A

FACTORY-INSTALLED NON-COMBUSTIBLE BOARD

DO NOT REMOVE

A

B

BV4236DBI

inches

39-3/4

41

millimeters

1010

1041

BV4842DBI

inches

41-3/4

48

millimeters

1060

1219

MEASUREMENTS FROM

TOP EDGE OF THE OPENING

5

10

11

12

2-1/2

13

14

15

16

17

18

19

32

TO CEILING

9

10

11

12

8

7

6

5

4

3

25

18

1 in. (25 mm) min.

to perpendicular wall

A

3-1/2 in. (89 mm) min.

from fireplace opening

to perpendicular wall

B

Mantel Leg or

Perpendicular Wall

Top of

Appliance

Drywall

A

B

Advertising