D. electrical service and repair, E. junction box installation, Notice: do not wire 110 vac to wall switch – Hearth and Home Technologies Hearth&Home Fireplace BV4236DBI User Manual

Page 31

Advertising
background image

31

Hearth & Home Technologies • BV4236DBI, BV4842DBI • 2209-900 Rev. N • 9/12

W

H

T

W

HT

BL

K

B

LK

GRN wire
inside box

Copper
ground attached
to GRN screw with
GRN wire

14/2WG

Cover Plate
outside firebox

Romex
Connector

D. Electrical Service and Repair

WARNING! Risk of Shock! Label all wires prior to dis-

connection when servicing controls. Wiring errors can

cause improper and dangerous operation. Verify proper

operation after servicing.

Figure 12.1 IPI Wiring Diagram

WARNING! Risk of Shock! Replace damaged wire with

type 105º C rated wire. Wire must have high temperature

insulation.

NOTE: 1. Ignition module, valve, pilot, and wall switch operate on

3 volts. 120 VAC is required at junction box unless equipped with

battery back-up.

TO JUNCTION

BOX (110V)

MODULE

FLAME

SENSE

IGNITER

RC100 RC200 RC300

(OPTIONAL WALL CONTROLS)

GROUND

ORANGE

(PILOT)

GREEN

(MAIN)

BROWN

BLACK

RED

BATTERY PACK

6V DC

FLAME

MODULATION

THERMOSTAT WIRE

ASSEMBLY / WALL

SWITCH WIRE

HIGH LIMIT

SWITCH

Figure 12.2 Junction Box Detail

NOTICE: DO NOT wire

110 VAC to wall switch.

E. Junction Box Installation

If the box is being wired from the

INSIDE of the appli-

ance:
• Remove the screw attaching the junction box/receptacle

to the outer shell, rotate the junction box inward to dis-

engage it from the outer shell (see Figure 12.2).

• Pull the electrical wires from outside the appliance through

the opening into the valve compartment and secure wires

with a Romex connector. See Figure 12.2.

• Make all necessary wire connections to the junction

box/receptacle and reattach the junction box/receptacle

to the outer shell.