3 “3-wire voltage” amplifiers – Honeywell SC1000 User Manual

Page 100

Advertising
background image

page 100 008-0608-00

12.2.3 “3-wire

Voltage” Amplifiers

Use the following wiring diagram when connecting an amplified transducer or in-line
amplifier with a 3-wire voltage amplifier to a High-Level Input channel. Examples of
such devices include

transducers with Option 2c or Option 2t internal amplifiers (with shunt cal)

Models UV or UV-10 Universal In-Line amplifiers (with shunt cal)

The High-Level Input channel’s Configuration Jumpers must be set as follows for
proper operation. See “Excitation and Signal Jumpers” on page 106.

(+)Excitation supply: “+28 VDC”

(-)Excitation supply: “GND”

Signal type: “voltage”

Signal reference: “differential”

Figure 12-2: “3-wire Voltage Amp” Connection to High-Level Input Channel

Advertising