Stick on label, Check the appliance is gas sound, Pressure testing – Heartland Bakeware U109760-02 User Manual

Page 47

Advertising
background image

SERVICING - WARNING

Disconnect from electricity and gas before servicing. Check appliance is safe when you have finished.

47

U109760-02

Lift up the ends of the plastic clips (one each
side) to release the catches holding the drawer
to the side runners and at the same time pull the
drawer forward and away from the side runners.
For safety’s sake push the drawer runners back
out of the way.

The regulator is now accessible.

The regulator may be one of two types.

Type 1

Unscrew the hexagonal nut in the front of the
regulator. The regulator nut has a plastic snap
in converter device on the underside, to convert
the regulator snap the device out of the nut and
refit the other way up.

set for Natural gas

set for Propane gas

The snap in converter device is marked to show
which gas it is set for. Make sure the device is
secure in the base of the nut and refit the nut to
the regulator.

Type 2

The regulator has a

bayonet mounted top

cap.
Using a small coin

press in and turn the

cap to remove it.

Turn the cap over so that the letters “LP” are
visible on base of the hollow in the cap. Refit
the cap making sure that the bayonet pins are
securely located.

set for Natural gas

set for Propane gas

Stick on label

Stick the appropriate label on to the data badge
to indicate the gas the appliance is now set for.

Check the appliance is gas sound.

When all connections have been re-made, make
sure all range controls are in the off position
and turn on the main gas supply valve. Use a
liquid leak detector at all joints and connections
to check for leaks in the system. Use a product
specifically manufactured for leak detection.
Leak testing of the appliance shall be conducted
in accordance to the manufacturer’s instructions.

Pressure Testing

Connect the appliance to the gas supply. Check
the appliance is gas sound.

The gas pressure can be measured at the
pressure test point on the appliance side of the
pressure regulator.