Setting the internal alarm buzzer, Setting the hard drive override, Figure 3-3 – Honeywell HRTL-One User Manual

Page 30: System setup menu

Advertising
background image

Rev 1.00

20

Document 900.0259

10/04

System Setup

P

Figure 3-3

System Setup Menu

Setting the Internal Alarm Buzzer

To enable or disable the internal alarm buzzer:

1.

On the System screen (Main Menu

System), press S or T to select Buzzer,

then press Enter.

2.

Press S or T to enable or disable the internal alarm buzzer. Options are:

ON = Buzzer is on. When the HRTL-One detects an alarm trigger (for example,
when the hard drive is full) a buzzer sounds to alert the user.

OFF = Buzzer is off.

3.

Press Menu to confirm your change.

4.

Press S or T to move to another field on the System screen or press Menu to exit
this screen and confirm the current operation.

5.

If you have completed all your system configuration changes, press Menu again to
exit and close menu setup.

Setting the Hard Drive Override

When the hard drive is full you can either:

Have the HRTL-One overwrite the hard drive, OR

Have the HRTL-One stop recording

1.

On the System screen (Main Menu

System), press S or T to select HDD

Overwrite, then press Enter.

2.

Press S or T to enable or disable the hard drive overwrite option. Options are:

YES = The HRTL-One overwrites the data on the hard drive when the drive is full.

NO = Turns auto reverse off. The HRTL-One stops recording when the drive is full.

3.

Press Menu to confirm your change.

(System)

Buzzer: On
HDD Overwrite: No
Message Latch: No
Date Display: Y-M-D
Date: 2002-JUL-14(SUN)
Time: 22:38:29
New Password: xxxx
Clear HDD: No
System Reset: No

J