Clearances
• Minimum distance between the cooktop and a side wall above the cooktop surface is 6”
(see dim "J" in Table 2 on next page)
• Depth of cutout must not exceed 25”. (see dimension G) Air intake slots on underside of control panel must
not be obstructed

or covered.

Electrical requirements:
• Electrical hookup must be done by a licenced electrician
• 120 Volts 60Hz .375 kW 3 prong plug 5 ft-(1.5 m) power cord included.

Gas Requirements:
• Gas hook-up must be done by a licensed gas fitter.
• Pressure requirements: Natural gas: 6” W.C. (min); LP gas: 11” W.C. (min)
• Connection: 1/2” NPT
• An accessible manual shut off valve must be installed at the appliance.
• Note: This unit contains a pre-set regulator.
• Natural Gas/Propane Conversion kits are available - must be done by a licensed gas fitter

Figure 1

Dim

30" Metro Cooktop

A

26 5/8" (68cm)

B

8 1/4" (21cm)

C

29 3/4" (76 cm)

D

1

Standard profile:12 3/4"(32 cm)

(as shown in diagram)

D

2

low profile: 10 1/8" (26 cm)

D

3

high back w/ shelf:

28 1/4" (72cm)

Table 1

Air intake slots on underside
of control panel must not be
obstructed or covered.

A

B

C

D

1

2

3

D

D

Installation Diagram- 30” Metro Cooktop Model 3805