Chapter 4: Routine Maintenance

Use the Control Center to Gather the Calibration Data

1.

Open the Control Center program.

2.

Select Tools>Size Calibration from the Menu Bar. The win-

dow in Figure 30 will appear:

3.

Press the Send Size Plot button to print the factory stored

calibration box. The printer will print a box that is 40” (102-cm)

long on the X-axis and 30-in (76-cm) wide on the Y-axis.

4.

Precisely measure both sides (X) and the top and bottom (Y) of

the box and record the results. Better accuracy in measurement

equals better calibration.

5.

Take the average of the horizontal (Y) values by adding them

together and dividing by 2. Repeat this procedure for the verti-

cal (X) values.

Example:

If X1 = 39.750-in and X2 = 39.700-in

The sum is 79.450-in (39.750-in + 39.700-in = 79.450-in)

The average is 39.725-in (79.450-in / 2 = 39.725-in)

The X calibration value is the average, 39.725-in

Enter the Calibration Data:

1.

Enter the measured values in the boxes in the Calibration win-

dow. Make sure the printer is in START (green light) mode.

Select the Set Calibration button.

2.

The Control Center will send the calibration values to the

printer and the new Calibration Setting will be displayed in

the boxes in the window pictured in Figure 31.

3.

Click on Done when finished.

Figure 30. The Calibration box and measurements.

Y1

Y2

X1 X2

~40 in.

Only use

Reset Calibration to

restore original factory calibration

settings.

Note

i

The factory-set calibration values

are written on a small sticker on

the under side of the right end

cover. (See Figure 33.)

Hint

The

Get Plotter Data button

will read the stored calibration

settings from the printer and dis-

play them in the

Factor windows.

Hint