54

Ioline FlexJet E User Guide

A marker plot doesn’t start at the correct point on the paper

Cause:

The origin is not set.

Solution:

Position the pen where the plot

should start. Press the

Set Origin key.

The printer does not complete the marker.

Cause:

1. Outdated software.

2. The frame/panel size is mis-

matched between the printer

and the design software.

Solution:

1. Visit the Ioline Web site to

download upgrades. Or, contact

Ioline Customer Service.

2. Check the panel size in the

software. It should be equal to or

lower than the printer panel size.

Send plot files from FlexPlot.

When a marker plot file is sent, nothing happens.

Cause:

A communication problem has oc-

curred or the printer is in

STOP

(red light) mode.

Solution:

Make certain the communication port

is connected and configured properly.

Position the marker on the carriage

where the plot should start and press

the

Set Origin key to put the printer

in

START (green light) mode.

No power when printer is turned on; keypad lights stay dark.

Cause:

1. The power cord is damaged or

disconnected.

2. The printer is damaged and

needs professional service.

Solution:

1. Check the power connection.

2. Contact an Ioline distributor or

Ioline Customer Service.

Poor line quality.

Cause:

1. Ink cartridge is improperly

installed.

2. Frame Gap setting is incorrect.

3. Carriage electronics or cables

are damaged.

4. Ink cartridge is empty.

Solution:

1. Remove and reinstall ink car-

tridge.

2. Use the

Control Center to

adjust frame gap as shown in

the Routine Maintenance

chapter.

3. Contact Ioline customer service.

4. Install a new ink cartridge.

Common Issues