Henny Penny PRESSURE FRYERS 600 User Manual

Page 20

Advertising
background image

Model 500/600

7. Turn main power switch to ON position.

8. Wait about 45 seconds for the burner to light.

9. Listen for the gas burner ignition.

• It will be an audible sound due to the gas igniting at the gas

jets within the burner.

10. The burner lights and operates until the shortening temperature

reaches a preset temperature, and lights.

Do not leave the burner on for more than 10 seconds
without shortening in the frypot or damage to the frypot may
result.

Shutdown Procedure

1. Turn main power switch to OFF position.

2. Turn the gas valve knob counterclockwise to the OFF position.

2-10. GAS PILOT & BURNER

LIGHTING AND
SHUTDOWN
PROCEDURE (Continued)

2-10

1207

2-11. PILOT FLAME

ADJUSTMENT

The pilot flame is preset at the factory. If adjustment is necessary,
contact your local independent Henny Penny distributor.

2-12. PRESSURE

REGULATOR
ADJUSTMENT
(GAS ONLY)

The gas regulator is preset at the factory at 3.5 inch water column
(0.87 kPa) for natural gas (10.0 inch (2.49 kPa) for propane). If
adjustment is necessary, contact your local independent Henny Penny
distributor.

Advertising