Model 500/600

DISPLAY

CAUSE

PANEL BOARD CORRECTION

“E-15”

Drain switch

Close drain, using the drain valve handle; if display still

“DRAN IS failure

shows “E-15”, have the drain microswitch checked

OPEN”

“E-20C”

Ignition module(s)

Turn switch to OFF, then back to COOK to try the ignition

(SSI gas fryers failure

process again, and if “E-20C” persists, have ignition modules

only)

checked

“E-20D”

No ignition

Turn switch to OFF, then back to COOK to try the ignition

(SSI gas fryers

process again, and if “E-20D” persists, have gas valve and gas

only)

flow checked

“E-41”

Programming

Turn switch to OFF, then back to COOK; if display shows any

“E-46”

failure

of the error codes, try to reinitialize the control (Section 2-3);
if error code persists, have the control board replaced

“E-70A”

Missing or broken

Have jumper wire between pins 1 and 2 checked

wire in pins 1 and
2 of P11 connector,
or faulty connector

Faulty I/O board

Have I/O board checked and replaced, if necessary

“TEMP TOO”

Possible water

Make sure oil is in frypot and at the proper level

LOW FOR

in frypot

PRESSURE”

3-2. ERROR CODE TABLE