2-13. ELECTRICAL

REQUIREMENTS
(ELECTRIC FRYER)

The electric fryer is available from the factory wired for 208, 220/240,
or 440/480 volts, single or three phase, 60 Hertz service. The proper
power service cable must be ordered as an accessory or provided at
installation. Check the data plate on the inside of the fryer door to
determine the correct power supply.

This fryer must be adequately and safely grounded (earthed)
or electrical shock could result. Refer to local electrical
codes for correct grounding (earthing) procedures or in
absence of local codes, with The National Electrical Code,
ANSI/NFPA No. 70-(the current edition). In Canada, all
electrical connections are to be made in accordance with CSA
C22.1, Canadian Electrical Code Part 1, and/or local codes.

To avoid electrical shock, this appliance must be equipped

with an external circuit breaker which will disconnect all
ungrounded (unearthed) conductors. The main power switch
on this appliance does not disconnect all line conductors.

The field supply wiring to the fryer should be of the size indicated in the
data table. It should be an insulated copper conductor rated for 600
volts and 90°C. For runs longer than 50 feet (15.24 m), use the next
larger size wire.

Permanently connected electric fryers with casters must be installed
with flexible conduit and a cable restraint, when installed in the
United States. See illustration at left. Holes are available in the
rear fryer frame for securing the cable restraint to the fryer. The
cable restraint does not prevent the fryer from tipping.

Data Table

Supply Wiring and Fusing for Electric Fryer

Supply

Min.

Wire

Fuse

Volts

Phase

KW

Amps

Size

Size

208

Single

11.25

54

6

90

208

Single

13.50

65

4

100

208

Three

11.25

31

10

50

208

Three

13.50

38

8

60

240

Single

11.25

47

6

80

240

Single

13.50

56

6

90

240

Three

11.25

27

10

45

240

Three

13.50

33

8

50

480

Three

11.25

14

14

25

480

Three

13.50

16

14

25

1207

2-11

DRYWALL CONSTRUCTION

Secure I-bolt to a building stud. Do
not attach to drywall only. Preferred
installation is approximately six
inches to either side of service.
Cable restraint must be at least six
inches shorter than flexible conduit.