Henny Penny PRESSURE FRYERS 600 User Manual

Page 60

Advertising
background image

Model 500/600

5-2. ERROR CODES

This section provides error codes and their
information in the form of an easy-to-read table.

If a problem occurs during the first operation of a
new fryer, recheck the Installation Section .

5-3. ERROR CODE TABLE

In the event of a control system failure, the digital
display shows an error message coded as follows:
“E-4”, “E-5”, “E-6”, “E-10”, “E-15”,
“E-20-A, B, D”, “E-41”, “E-46”, & “E-70.
An alarm sounds when an error code is displayed,
and to silence this alarm, press any button.

DISPLAY

CAUSE

PANEL BOARD CORRECTION

“E-4”

Control board

Turn switch to OFF position, then turn switch back to ON;

“CPU TOO

overheating

if display shows “E-4”, the control board is getting too hot;

HOT”

check the louvers on each side of the unit for obstructions;
check cooling fan, if present

“E-5” “OIL

Shortening

Turn switch to OFF position, then turn switch back to ON; if

TOO HOT”

overheating

display shows “E-5”, the heating circuits and temperature
probe should be checked

“E-6A”

Temperature

Turn switch to OFF position; then turn switch back to ON; if

“OIL PROB

probe open

display shows “E-6”, have the temperature probe checked

OPEN”

“E-6B”

Temperature

Turn switch to OFF position, then turn switch back to ON; if

“OIL PROB

probe shorted

display shows “E-6”, have the temperature probe checked

SHRT”

“E-10”

High limit

Reset the high limit by manually pushing up on the reset

“HIGH

button; if high limit does not reset, high limit must be

LMT TRIP”

replaced

5-2