Henny Penny PRESSURE FRYERS 600 User Manual

Page 23

Advertising
background image

Model 500/600

1207

2-13

Step 4

2-15. CHECKING THE

FILTER PUMP

Use the following testing procedure on new or cold fryers.

1. Open the front door of the fryer.

2. Loosen the filter union connection.

3. Turn the main power switch to the PUMP position.

Open the filter valve. You will hear the electric
motor running.

Only run the pump for a few seconds or damage to the
pump could result.

4. Place your thumb over the open filter union flare. You should feel

suction. Close the filter valve. Turn off the pump.

2-16. MOTOR BEARINGS

The electric motor bearings are permanently lubricated. DO NOT
LUBRICATE.

This completes the testing cycle. If any of the functions did not occur,
recheck the installation. If a problem persists, refer to other sections of
this manual or call an authorized Henny Penny distributor.

2-17. OPERATIONAL

CHECKS

1. Check to see that the indicator needle in the pressure gauge is

reading in the Operating Zone.

• If pressure does not build, contact your local Henny

Penny service office.

2. Check the drain valve and filter valve for leaks.

3. At the end of cook cycle:

• The timer will sound.

• The fryer automatically depressurizes.

Advertising