Setting current day and time, Iv deluxe programmable thermostats, Number 2 must be set to 1 to extend fan operation – Honeywell CHRONOTHERM T8602D User Manual

Page 9

Advertising
background image

T8600D, T8601D AND T8602D CHRONOTHERM

®

IV DELUXE PROGRAMMABLE THERMOSTATS

68-0164—1

9

Table 6. Thermostat Installer Setup Options (continued).

M10312

Time

Set Program

System

Fan

Run

Program

Hold Temp

Set Current

Day/Time

Set Current

Day/Time

Wake

Leave

Return

Sleep

Day

Heat/Cool

Settings

Daylight

Time

Copy

Mon

PM

Set Day/Time

M10313

Time

Set Program

System

Fan

Run

Program

Hold Temp

Set Current

Day/Time

Wake

Leave

Return

Sleep

Day

Day

Heat/Cool

Settings

Daylight

Time

Copy

PM

Tue

Set Day/Time

IMPORTANT

Review the settings to confirm that they match the
system. Press Run Program to exit the Installer
Setup. The thermostat has saved the Installer Setup
changes and initiated a reset in order to operate with
these new settings. Be sure to set the current day
and time immediately.

Setting Current Day and Time

1. Press Set Current Day/Time.

NOTE:

On initial power up or after an extended power
loss, 1:00 pm flashes on the display until a key
is pressed.

2. Press Day until the current day is displayed.

NOTE:

Sun=Sunday, Mon=Monday, Tue=Tuesday,
Wed=Wednesday, Thu=Thursday, Fri=Friday,
Sat=Saturday.

M10314

Time

Set Program

System

Fan

Run

Program

Hold Temp

Set Current

Day/Time

Wake

Leave

Return

Sleep

Day

Time

Heat/Cool

Settings

Daylight

Time

Copy

AM

Tue

Set Day/Time

3. Press Time

or Time

until the current time is

displayed.

NOTE:

Tapping the Set Current Day/Time will change
the time in one hour increments.

Installer Setup

Number (Press

Time

key to

Factory-Setting

Other Choices

(Press

or

key to change)

Actual

Select

change)

Display

Description

Display

Description

Setting

Not used

31 and 32

Minimum off time
for the
compressor

33

5

5 minute minimum off
time for the
compressor

0 thru 4

Minimum number of minutes (0
thru 5) the compressor will be
off between calls for the
compressor

Temperature
range stops in
heating

34

90

Highest setpoint
heating can be set to

40 to 89

Temperature range (1°F
increments) heating setpoint
can be set to

Temperature
range stops in
cooling

35

45

Lowest setpoint
cooling can be set to

46 to 99

Temperature range (1°F
increments) cooling setpoint
can be set to

Not used

36

Temperature
display
adjustment

37

0

No difference in
displayed temperature
and actual room
temperature

3 thru -3

1—Display adjusts to 1°F

higher than actual room
temperature

2—Display adjusts to 2°F

higher than actual room
temperature

3—Display adjusts to 3°F

higher than actual room
temperature

-1—Display adjusts to 1°F lower

than actual room temperature

-2—Display adjusts to 2°F lower

than actual room temperature

-3—Display adjusts to 3°F lower

than actual room temperature

a

Number 2 must be set to 1 to extend fan operation.