Table 12. Troubleshooting Information (continued).

Symptom

Possible Cause

Action

Heating or cooling
come on
momentarily and
shut off

Heat or cool circuit is opening
up or becoming high
impedance.

Add resistor in parallel with load or install interface relay.

System on indicator
(flame=heat,
snowflake=cool) is
displayed, but no

Fan operation set for 0
(conventional heat) when it
should be set for 1 (electric
heat).

Enter Installer Setup number 2 and reconfigure the fan operation.

warm or cool air is
coming from the
registers.

Conventional heating
equipment turns on the fan
when the furnace has
warmed up to a setpoint.

Wait a minute after seeing the on indicator and then check the registers.

Heating or cooling equipment is
not operating.

Verify operation of heating or cooling equipment in self-test.

Outdoor
temperature not
displayed

a

Option not activated.

Enter Installer Setup number 24 and set to 1. Thermostat must have OT
terminals and a C7089B1000 installed.

Outdoor
temperature

Outdoor sensor is connected
incorrectly.

Refer to C7089B1000 installation instructions and check wiring between
the thermostat and sensor.

display is incorrect

a

Wrong sensor.

Replace sensor with C7089B1000 sensor.

a

Available on select models.

Feature/Function

Chronotherm® III Family

Chronotherm® IV Family

Programming

5-1-1 day programming

7-day programming

Changeover

Automatic or manual changeover models
available

Automatic/manual changeover selectable

Installer configuration

Field settings made via screws on the back of
the thermostat

Field settings made through the keyboard

System switching

Mechanical switch

Keyboard entry

Fan switching

Mechanical switch

Keyboard entry

Device color

Beige or Premier White® color

Taupe or Premier White® color

CROSS REFERENCE

All SUPER TRADELINE® Chronotherm® IV thermostats are
different from the existing Chronotherm® III devices as
summarized in Table 13.

Refer to Table 14 for thermostat cross referencing information.

Table 13. Differences Between Chronotherm® III Thermostats and Chronotherm® IV Thermostats.

Advertising