T8600D, T8601D AND T8602D CHRONOTHERM

®

IV DELUXE PROGRAMMABLE THERMOSTATS

68-0164—1

4

INSTALLATION

When Installing this Product...

1. Read these instructions carefully. Failure to follow the

instructions can damage the product or cause a
hazardous condition.

2. Check the ratings given in the instructions and on the

product to make sure the product is suitable for your
application.

3. Installer must be a trained, experienced service

technician.

4. After completing installation, use these instructions to

check out the product operation.

Location

Install the thermostat about 5 ft (1.5m) above the floor in an
area with good air circulation at average temperature. See
Fig. 2.

Do not install the thermostat where it can be affected by:

drafts, or dead spots behind doors and in corners.

hot or cold air from ducts.

radiant heat from sun or appliances.

concealed pipes and chimneys.

unheated (uncooled) areas such as an outside wall
behind the thermostat.

Wallplate Installation

The thermostat can be mounted horizontally on the wall or on
a 2 in. x 4 in. wiring box. Position wallplate horizontally on the
wall or on a 2 in. x 4 in. wiring box.

5 FEET

[1.5 METERS]

YES

NO

NO

NO

M10106

1. Position and level the wallplate (for appearance only).

The thermostat will function properly even when not
level.

2. Use a pencil to mark the mounting holes. See Fig. 3.
3. Remove the wallplate from the wall and drill two 3/16

inch holes in the wall (if drywall) as marked. For firmer
material such as plaster, drill two 7/32 inch holes.
Gently tap anchors (provided) into the drilled holes until
flush with the wall.

4. Position the wallplate over the holes, pulling wires

through the wiring opening.

5. Loosely insert the mounting screws into the holes.
6. Tighten mounting screws.

WIRING

All wiring must comply with local electrical codes and
ordinances. Follow equipment manufacturer wiring
instructions when available. Refer to Fig. 15 through 20 for
typical hookups. A letter code is located near each terminal
for identification. Refer to Table 4 for terminal designations.

CAUTION

Disconnect power before wiring to prevent electrical
shock or equipment damage.

1. Loosen the terminal screws on the wallplate and

connect the system wires. See Fig. 4

Fig. 2. Typical location of thermostat.