Fig. 7, Fig. 6, Fig. 8 – Hoshizaki FD-1001MRH(-C) User Manual

Page 20

Advertising
background image

20

THREAD

SEALANT

Threads

Diaphragm

O-Ring

Fig. 7

POLYOL

ESTER

(POE) OIL

Brush

Male Fitting

Apply POE Oil to
Entire Male Fitting

DO NOT USE

THREAD SEALANT

Fig. 6

Female Coupling

3/8" OD Discharge Line

(Insulated)

Remote Condenser Unit

1/4" OD Liquid Line

(Insulated)

Icemaker

Male Fitting

Service Loop

c. Make sure the male fitting and female coupling are properly aligned, then start the

connection by hand to ensure that it is not cross threaded.

d. Place a backup wrench on the back of the female coupling, then tighten the

connection with a wrench until it is tight. At this point, the nut has covered most of
the threads on the male fitting.

CAUTION! Failure to use a backup wrench may

result in damage to the line set and possible refrigerant leaks.

e. Mark a reference line on the female coupling and the remote condenser unit or

icemaker panel. Using a backup wrench on the back of the female coupling, tighten
the six-sided nut of the female coupling an additional 1/6 turn. See Fig. 8.

Backup

Wrench

Reference Line

1/6 Turn

Wrench

Wrench

Backup

Wrench

After Tight, Tighten an
Additional 1/6 Turn

Fig. 8