3. Infrared Sensor Shutdown Delay

This is the delay between the infrared sensor detecting ice and the start of the shutdown
sequence. The infrared sensor shutdown delay is factory-adjusted to 100 seconds and
no adjustment is required for most dispenser unit/storage bin applications.

a) Standard Storage Bin:

When installed on a standard storage bin, any shutdown delay setting is acceptable.

b) Dispenser Unit:

For typical dispenser unit applications, a 100-second shutdown delay is recommended.
However, on some dispenser unit applications, the ice level at shutoff may need to be
adjusted depending on the dispenser agitation or dispense method. Should a different
shutdown delay be desired, adjust S1 dip switch 1, 2, and 3 to obtain the shutdown
delay needed. See the table below. For further details, contact Hoshizaki Technical
Support at 1-800-233-1940.

Note: When the shutdown sequence begins, the compressor de-energizes immediately

and then 5 minutes later the gear motor and fan motor de-energize.

WARNING

Increasing the shutdown delay allows a higher level of ice in the dispensing
unit/storage bin before shutdown. This could lead to icemaker movement or ice
overflow.

S1 Dip Switch

Shutdown Delay

NO. 1 NO. 2 NO. 3

OFF

OFF

OFF

0 seconds

ON

OFF

OFF

100 seconds (1.6 minutes)

OFF

ON

OFF

1100 seconds (18.3 minutes)

OFF

OFF

ON

1650 seconds (27.5 minutes)

ON

ON

OFF

2200 seconds (36.7 minutes)

OFF

ON

ON

0 seconds

ON

ON

ON

0 Seconds