1. Icemaker
• If you would like to convert to top water supply, install the optional Top Water Supply Kit

(HS-2123).

• Icemaker water supply inlet is 1/2" female pipe thread (FPT). A minimum of 3/8" OD

copper tubing is recommended for the icemaker water supply line.

• An icemaker water supply line shut-off valve and drain valve should be installed.
• Icemaker drain outlet is 3/4" FPT. A minimum of 3/4" OD hard pipe is recommended for

the icemaker drain line.

2-inch

(5-cm) air

gap

Floor

Drain

FD-1001MAH(-C)
FD-1001MRH(-C)
FD-1001MLH(-C)

Separate piping to approved drain.

Leave a 2-inch (5-cm) vertical air

gap between the end of each pipe

and the drain.

Icemaker Water

Supply Line

Shut-Off Valve

Icemaker Water

Supply Line

Drain Valve

Icemaker

Icemaker Water

Supply Inlet

1/2" FPT

Bin Drain Outlet

3/4" FPT

Icemaker

Drain Outlet

3/4" FPT

To convert to top water supply,

install the optional Top Water

Supply Kit (HS-2123).

Storage Bin

Fig. 14