C. preparing the icemaker for long storage, C. preparing the icemaker for long storage caution – Hoshizaki FD-1001MRH(-C) User Manual

Page 42

Advertising
background image

42

Maintenance Schedule (continued)

Frequency Area

Task

After
3 Years,
then Yearly

Upper Bearing
(extruding head);
Lower Bearing
and O-Ring
(lower housing);
Mechanical
Seal; Evaporator
Cylinder; Auger

Inspect. Replace both upper bearing and lower bearing if wear exceeds
factory recommendations. Replace the mechanical seal if the seal's contact
surfaces are worn, cracked, or scratched.

C. Preparing the Icemaker for Long Storage

CAUTION

When storing the icemaker for an extended time or in sub-freezing
temperatures, follow the instructions below to prevent damage.

When the icemaker is not used for two or three days under normal conditions, it is
sufficient to only move the power switch to the "OFF" position. When storing the
icemaker for extended time or in sub-freezing temperatures, follow the instructions
below.

1. Remove the water from the icemaker water supply line:

1) Turn off the power supply, then remove the front panel.
2) Move the power switch to the "OFF" position.
3) Close the icemaker water supply line shut-off valve, then open the icemaker water

supply line drain valve.

4) Allow the line to drain by gravity.
5) Attach a compressed air or carbon dioxide supply to the icemaker water supply line

drain valve.

6) Move the control switch to the "ICE" position, then move the power switch to the "ON"

position. Replace the front panel in its correct position, then turn on the power supply.

7) Blow the icemaker water line out using the compressed air or carbon dioxide supply.
8) Close the icemaker water supply line drain valve.

2. Drain the evaporator:

1) Turn off the power supply, then remove the front panel.
2) Move the control switch to the "DRAIN" position, then replace the front panel in its

correct position.

3) Turn on the power supply and allow the water system to drain for 5 minutes.
4) Turn off the power supply, then remove the front panel. Move the power switch to the

"OFF" position.

5) Remove the evaporator drain line hose from the evaporator and attach a compressed

air or carbon dioxide supply to the hose.

Advertising