2. Water-Cooled Condenser

a) Connection to an Open Drain System
• Condenser water supply inlet is 1/2" female pipe thread (FPT). A minimum of 3/8" OD

copper tubing is recommended for the condenser water supply line.

• A condenser water supply line shut-off valve and drain valve should be installed.
• Condenser drain outlet is 3/8" FPT. A minimum of 3/8" OD hard pipe is recommended for

the condenser drain line.

• In some areas, a back flow preventer may be required in the cooling water circuit.

FD-1001MWH(-C)
Condenser
Connection
to a Potable
Water Supply

Separate piping to approved drain.

Leave a 2-inch (5-cm) vertical air gap

between the end of each pipe and the

drain.

2-inch

(5-cm) air

gap

Floor

Drain

Condenser Water

Supply Inlet

1/2" FPT

Condenser Drain

Outlet 3/8" FPT

Icemaker/Condenser

Water Supply Line

Shut-Off Valve

Icemaker/Condenser

Water Supply Line

Drain Valve

Icemaker

Icemaker Water

Supply Inlet

1/2" FPT

Bin Drain Outlet

3/4" FPT

Icemaker

Drain Outlet

3/4" FPT

To convert to top water supply,

install the optional Top Water

Supply Kit (HS-2123).

Storage Bin

Fig. 15