7) Connect the refrigerant lines to the appropriate fittings on the rack system first (if not

already brazed on), then at the icemaker.
If the couplings to the rack system are not Parker quick connect couplings, follow the
coupling manufacturer's instructions. Make a proper Parker quick connect coupling
connection as follows:

a. Remove the protective covers from the male fitting and female coupling.
b. Apply Polyol Ester (POE) refrigerant oil to the entire male fitting, including threads,

o-ring, and diaphragm, before making the connection. See Fig. 12.

CAUTION

Do not use thread sealant on the fittings. Use POE refrigerant oil only.

c. Make sure the male fitting and female coupling are properly aligned, then start the

connection by hand to ensure that it is not cross threaded.

d. Place a backup wrench on the back of the female coupling, then tighten the

connection with a wrench until it is tight. At this point, the nut has covered most of
the threads on the male fitting.

CAUTION! Failure to use a backup wrench may

result in damage to the line set and possible refrigerant leaks.

e. Mark a reference line on the female coupling and the unit panel. Using a backup

wrench on the back of the female coupling, tighten the six-sided nut of the female
coupling an additional 1/6 turn. See Fig. 13.

8) Open the rack system service valves.

Female Coupling

(Charging Ports)

3/8" OD Suction Line

(Insulated)

Rack System-Threaded Connection

1/4" OD Liquid Line

(Insulated)

Icemaker

Male Fitting

Service Loop

Fig. 11

Female Threaded Coupling

Rack System-Braze Connection

Male Threaded Fitting

3/8" OD Suction Line

(Insulated)

1/4" OD Liquid Line

(Insulated)

3/8" OD Suction Line

(Insulated)

1/4" OD Liquid Line

(Insulated)

Braze Conneciton