Heat & Glo • Escape-I35-C, Escape-I30-C • 2201-901 Rev. K • 1/13

Figure 3.1 IPI Pilot Flame Patterns

Burner Ignition and Operation

Frequency: Annually

By: Service Technician

Tools needed: Protective gloves, vacuum cleaner, whisk
broom, fl ashlight, voltmeter, indexed drill bit set, and a
manometer.

• Verify burner is properly secured and aligned with pilot

or igniter.

• Clean off burner top, inspect for plugged ports, corrosion

or deterioration. Replace burner if necessary.

• Replace Glowing embers with new dime-size pieces.

DO NOT block ports or obstruct lighting paths. Refer to
Section 12 for proper ember placement.

• Verify batteries have been removed from battery back-up

IPI systems to prevent premature degradation due to
long term heat exposure.

• Check for smooth lighting and ignition carryover to all

ports. Verify that there is no ignition delay.

• Inspect for lifting or other fl ame problems.

• Verify air shutter setting is correct. See Section 12 for

required air shutter setting. Verify air shutter is clear of
dust and debris.

• Inspect orifi ce for soot, dirt and corrosion. Verify orifi ce

size is correct. See Service Parts List for proper orifi ce
sizing.

• Verify manifold and inlet pressures. Adjust regulator as

required.

• Inspect pilot fl ame pattern and strength. See Figure 3.1

for proper pilot fl ame pattern. Clean or replace orifi ce
spud as necessary.

• Inspect IPI fl ame sensing rod for soot, corrosion and

deterioration. Polish with fi ne steel wool or replace as
required.

• Verify that there is not a short in fl ame sense circuit by

checking continuity between pilot hood and fl ame sense
rod. Replace pilot as necessary.