J. Air Shutter Setting

Air shutter settings should be adjusted by a qualifi ed ser-
vice technician at the time of installation. The air shutter is
set at the factory for minimum vertical vent run. Adjust air
shutter for longer vertical runs. See Figure 12.3.

NOTICE: If sooting occurs, provide more air by opening
the air shutter.

Figure 12.3 Air Shutter

Figure 12.2 Fixed Glass Assembly

I. Fixed

Glass

Assembly

WARNING! Risk of Asphyxiation! Handle fi xed glass
assembly with care. Inspect the gasket to ensure it is
undamaged and inspect the glass for cracks, chips or
scratches.

DO NOT strike, slam or scratch glass.

DO NOT operate fi replace with glass removed, cracked,

broken or scratched.

Replace as a complete assembly.

Removing Fixed Glass Assembly

• The glass assembly fastens to the fi replace in four

places. The fastening mechanisms are spring-loaded
glass latches. An example of the glass latch is shown
in Figure 12.2.

• To release glass assembly, pull the two top spring-loaded

latches forward and allow them to retract away from
the glass assembly. Slide the glass assembly outward
and downward until top of the glass frame will clear the
surround.

Replacing Fixed Glass Assembly

• Tilt glass assembly toward fi replace and slide glass

assembly downward to engage bottom latches. Verify
bottom latches are fully engaged and then fasten the
two top latches.

• Note that the extended glass latch tabs on the glass

frame are for the bottom glass latches.

Air Shutter Settings

NG

LP

ESCAPE-I30-C

1/4 in.

Full Open

ESCAPE-I35-C

1/4 in.

Full Open

GLASS

ASSEMBLY

LATCHES

(BOTH BOTTOM

AND TOP)

AIR SHUTTER